Other technical data
Class Appliance: 3
Appliance Category: II2EK3B/P;
II2L3B/P
Appliance gas supply: Natural
gas G25.3 (2EK) 25 mbar; G25
(2L) 25 mbar
This model is designed for use
with natural gas G25.3 25
mbar / G25 25 mbar but can be
converted for use with natural
gas G20 20 mbar, butane or
propane gas G30/G31 30/30
mbar providing the correct
injectors. The injectors not
supplied with the appliance have
to be ordered from After Sales
Service (refer to the Service
chapter).
TOTAL POWER
Gas original:
G25.3 (2EK) 25 mbar = 7.75 kW
G25 (2L) 25 mbar = 7.75 kW
Gas replacement:
G30/G31 (3B/P) 30/30 mbar = 567 g/h
G20 (2E) 20 mbar = 7.75 kW
Gas connection: R 1/2"
Burner type Injector mark
Nominal Pow-
er kW
Nominal Flow
g/h
Reduced
Power kW
by-pass
G25.3 25 mbar / G25 25 mbar
Rapid (large) 115x 2.75 - 0.75 42
Semi-rapid
(medium)
98x 2.0 - 0.45 32
Auxiliary
(small)
071 1.0 - 0.33 28